search query: @keyword transmission line / total: 8
reference: 3 / 8
« previous | next »
Author:Malinen, Vesa
Title:Voimajohtojen komposiittieristinten valintakriteerit ja kunnon arviointi
Selection criteria and condition assessment of transmission line composite insulators
Publication type:Master's thesis
Publication year:2014
Pages:ix + 99      Language:   fin
Department/School:Sähkötekniikan ja automaation laitos
Main subject:Sähköjärjestelmät   (S3015)
Supervisor:Lehtonen, Matti
Instructor:Jalonen, Mikko
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201411032977
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  2405   | Archive
Keywords:composite insulator
insulator selection
insulator inspection
transmission line
condition assessment
komposiittieristin
eristinten valinta
eristinten tarkastaminen
voimajohto
kunnon arviointi
Abstract (eng):Traditionally glass and porcelain insulators have been used in various high voltage applications.
During the last decades the use of composite insulators has been substantially increasing due to several beneficial characteristics associated with them.
These characteristics are mainly attributable to the polymer materials used in composite insulators.
In addition to the materials also the design and manufacturing techniques of composite insulators are different than those of traditional insulators.
Although current composite insulators are considered to be technically mature, the service experience with them is still more concise than with traditional insulators and some uncertainty still exists.
Because of the factors above, the selection and condition assessment of composite insulators is challenging for electric utilities.

This thesis presents technical factors that should be considered and properties that should be required as composite insulators are selected and acquired.
This thesis also studies the possibilities for in-service conditions assessment of composite insulators at Finnish transmission grid operator Fingrid Oyj.
First the possible inspection methods were evaluated based on the literature and then the most applicable method was used in trial inspection.

Based on the current knowledge summarized in this thesis several guidelines related to materials, designs, protective devices, dimensioning and testing are presented.
It was also discovered that the most applicable method for inspection and condition assessment is combined ultraviolet detection and infrared thermography.
This method was applied in trial helicopter inspection to assess composite insulators in service.
Based on the results of the trial inspection conclusions concerning the condition of inspected insulators and applicability of the inspection method are presented.
In addition future actions related to inspection and condition assessment of composite insulators are recommended to Fingrid Oyj.
Abstract (fin):Lasi- ja posliinieristimiä on perinteisesti käytetty erilaisissa suurjännitesovelluksissa.
Viime vuosikymmenten aikana komposiittieristinten käyttö on lisääntynyt huomattavasti niihin liitettyjen lukuisten hyvien ominaisuuksien vuoksi.
Nämä ominaisuudet liittyvät pääasiassa komposiittieristinten polymeerimateriaaleihin.
Materiaalien ohella myös komposiittieristinten rakenteet ja valmistustekniikat eroavat perinteisistä eristimistä.
Vaikka nykyisiä komposiittieristimiä pidetään teknisesti kypsinä, on niiden käyttökokemus perinteisiä eristimiä suppeampaa ja niihin liitetään yhä jonkin verran epävarmuutta.
Edelliset tekijät tekevät komposiittieristinten valinnasta ja kunnon arvioinnista haastavaa verkkoyhtiössä.

Tämän diplomityön ensimmäisenä tavoitteena oli löytää komposiittieristinten valinnassa huomioitavat tekniset tekijät ja sellaiset ominaisuudet, joita komposiittieristimiltä tulee hankittaessa vaatia.
Työn toisena tavoitteena oli selvittää voimajohtojen komposiittieristinten käytönaikaisen kunnon arvioinnin mahdollisuuksia Suomen kantaverkkoyhtiö Fingrid Oyj:ssä.
Ensin työssä arvioitiin kirjallisuuden perusteella erilaisia tarkastusmenetelmiä ja tämän jälkeen soveltuvinta menetelmää kokeiltiin käytännössä.

Diplomityössä tehdyn selvityksen perusteella esitetään useita komposiittieristinten materiaaleihin, rakenteisiin, suojavarusteisiin, mitoitukseen ja testaamiseen liittyviä suosituksia.
Kirjallisuuden perusteella komposiittieristinten tarkastamiseen ja kunnon arviointiin soveltuvimmaksi menetelmäksi osoittautui yhdistetty ultravioletti- ja infrapunalämpökuvaus.
Menetelmää kokeiltiin käytössä oleville eristimille helikopteritarkastuksessa.
Tarkastuskokeilun tulosten perusteella tehdään johtopäätöksiä tarkastettujen komposiittieristinten kunnosta sekä menetelmän soveltuvuudesta.
Lisäksi työssä annetaan jatkosuosituksia komposiittieristinten tarkastamiseen ja kunnon arviointiin Fingrid Oyj:ssä.
ED:2014-11-09
INSSI record number: 50019
+ add basket
« previous | next »
INSSI