search query: @keyword lämmönsiirrin / total: 9
reference: 3 / 9
« previous | next »
Author:Kontu, Matti Eino
Title:Vastapainevoimalaitoksen tehostamismahdollisuudet levylämmönsiirtimiä käyttäen
Possibilities to increase efficiency in CHP-powerplants by using plate heat exchangers
Publication type:Master's thesis
Publication year:2012
Pages:(9) + 67 s. + liitt. 7      Language:   fin
Department/School:Energiatekniikan laitos
Main subject:Energiatalous ja voimalaitostekniikka   (Ene-59)
Supervisor:Ahtila, Pekka
Instructor:Häggblom, Tobias
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  4690   | Archive
Keywords:combined heat and power powerplant
CHP
heat exchanger
total efficiency
yhteistuotanto
lämmönsiirrin
kokonaishyötysuhde
Abstract (eng): This master's thesis studies the opportunities to use plate heat exchangers in combined heat and power (chp) powerplants.
The primary object of the research is to examine the possibilities to increase the total efficiency of chp power plants by using Vahterus plate and shell heat exchangers.

The thesis consists of a theoretical part, which includes introductions to combined heat and power powerplants and heat exchangers in combined heat and power powerplants (chapters 2 and 3).
Chapter four studies the sizing of heat exchangers.
After this, a comparison is made between different kinds of heat exchangers in chp powerplants.
In the empirical part of the research, the conducted simulation and calculations made are explained.
The aim of the simulation and the calculations is to research whether the total efficiency of chp powerplants can be increased.

The simulation in this research was made based on process values from chp power plant example cases by Sweco Industry.
Furthermore, calculations were made based on process values from the example cases.
The heat exchanger sizing was made with a sizing program by Vahterus.
The purpose of using the Vahterus sizing programme was to ensure that the calculations were made on a realistic base.

According to the research, there is a possibility to increase the total efficiency in chp-powerplants by using Vahterus plate and shell heat exchangers.
However, the increase of total efficiency is rather small.
More specifically, the end customers' best added value comes from space saving.
Overall, Vahterus plate and shell heat exchangers fit well for the example chp-powerplants' district heat side and also for high-pressure preheater positions.
Abstract (fin): Tässä diplomityössä tutkitaan levylämmönsiirtimen käyttömahdollisuuksia vastapainevoimalaitoksissa.
Työn tärkeimpänä tavoitteena on tutkia voimalaitoksen kokonaishyötysuhteen parantamismahdollisuuksia Vahterus Oy:n hitsattujen levylämmönsiirtimien avulla.

Työ koostuu teoriaosasta, jossa tarkastellaan erilaisia vastapainevoimalaitoksia, vastapainevoimalaitoksissa käytettäviä lämmönsiirtimiä, lämmönsiirtimien mitoittamista sekä vertaillaan erityyppisten lämmönsiirtimien käyttöä vastapainevoimalaitoksissa.
Lämmönsiirtimien vertailun jälkeen työssä simuloidaan ja lasketaan voimalaitoksen kokonaishyötysuhteita sekä mitoitetaan Vahteruksen levylämmönsiirtimiä diplomityössä käytettyihin esimerkkiprosesseihin.

Tutkimusosion lämmönsiirrinmitoitusten avulla etsittiin prosessien asteisuuksien muutosmahdollisuuksia Vahterus Oy:n levylämmönsiirtimillä.
Lämmönsiirrinmitoitusten jälkeen voimalaitoslaskelmien avulla tutkittiin mahdollisia kokonaishyötysuhteen parantamismahdollisuuksia yhteistuotantolaitoksissa asteisuusmuutosten pohjalta.

Tutkimuksessa suoritetun simuloinnin ja laskelmien mukaan yhteistuotantolaitosten kokonaishyötysuhdetta on mahdollisuus parantaa.
Saavutettava kokonaishyötysuhteen kasvu on kuitenkin hyvin pientä ja asiakkaan suurin hyöty on tämän tutkimuksen mukaan levylämmönsiirtimen käytön avulla saavutettava tilansäästö.
Tutkimuksen mukaan Vahterus Oy:n levylämmönsiirtimien käytölle yhteistuotantolaitoksissa ei ole estettä ja ne soveltuvat esimerkkilaitoksissa niin lauhdutus- kuin korkeapainepuolellekin.