search query: @keyword elokuva / total: 9
reference: 2 / 9
« previous | next »
Author:Suppanen, Emma
Title:Inter-subject correlation of MEG data during movie viewing
Koehenkilöiden välisten korrelaatioiden laskeminen elokuvakatselun aikana kerätystä MEG-datasta
Publication type:Master's thesis
Publication year:2014
Pages:vii + 58      Language:   eng
Department/School:Sähkötekniikan korkeakoulu
Main subject:Biologinen tekniikka   (F3013)
Supervisor:Parkkonen, Lauri
Instructor:
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201412303344
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  2506   | Archive
Keywords:magnetoencephalography (MEG)
inter-subject correlation (ISC)
minimum norm estimate (MNE)
envelope correlation
movie
magnetoenkefalografia
koehenkilöiden välinen korrelaatio
elokuva
miniminormimenetelmä
verhokäyräkorrelaatio
Abstract (eng):Inter-subject correlation (ISC) is a measure for shared brain activity between subjects.
ISC method is a data-driven approach that has been widely exploited to study brain responses to natural stimuli using functional magnetic resonance imaging (fMRI) but only scarcely utilizing magnetoencephalography (MEG).
Natural stimuli are often too complex to be modelled explicitly but they are very useful in probing higher cognitive processes such as those supporting social interaction.

The inter-subject correlation method was used in this Thesis to analyze MEG recordings of eight movie spectators.
ISCs were assessed from the envelopes of the MEG signals in four frequency ranges (8--12, 14--22, 26--40 and 60--85 Hz) and from the steady-state response elicited by the 24-Hz frame rate of the movie.
Correlations were calculated at source level from time courses obtained with minimum-norm estimate (MNE).
Statistically significant correlations up to 0.22 plusminus 0.03 were found.
They occurred mainly in early visual, motor, and somatosensory cortices.
Abstract (fin):Koehenkilöiden välinen korrelaatio (ISC) on eräs tunnusluku sille, kuinka samankaltaista koehenkilöiden aivotoiminta on.
Aineistolähtöisenä menetelmänä koehenkilöiden välisten korrelaatioiden tarkastelu sopii luonnollisista koeasetelmista kerättävän datan analysointiin, sillä se ei tarvitse tietoa ärsykkeistä.
Luonnolliset ärsykkeet ovat otollisia tutkittaessa monimutkaisia kognitiivisia toimintoja, kuten esimerkiksi muistia tai sosiaalista kanssakäymistä, mutta usein liian monisyisiä mallinnettaviksi täsmällisesti.
Koehenkilöiden välisten korrelaatioiden laskeminen on laajasti käytössä toiminnallista magneettiresonanssikuvantamista (fMRI) hyödyntävissä tutkimuksissa, mutta magnetoenkefalografialla (MEG) mitattuun dataan sitä on sovellettu vain muutaman kerran.

Tässä diplomityössä koehenkilöiden välisiä korrelaatioita käytettiin kahdeksalta elokuvaa katsoneelta koehenkilöltä MEG:lla mitattujen aivovasteiden analysointiin.
Korrelaatiot laskettiin neljällä eri taajuuskaistalla (8--12 Hz, 14--22 Hz, 26--40 Hz and 60--85 Hz) MEG-signaalien verhokäyristä, sekä lisäksi elokuvan 24 Hz:n kuvataajuuteen liittyvästä näköaivokuoren jatkuvasta vasteesta.
Korrelaatiot selvitettiin lähdepisteittäin aivokuorelle miniminormimenetelmällä estimoiduista tunnusluvuista.
Suurimmat tilastollisesti merkittävät korrelaatiot (jopa 0.22 plusminus 0.03) löydettiin pääasiallisesti varhaisilta näkö-, liike- ja tuntoaivokuorilta.
ED:2015-01-18
INSSI record number: 50404
+ add basket
« previous | next »
INSSI